MOCHUAN MV series PLC ChaseCut Instruction Demo

MOCHUAN MV series PLC Chasecut Instruction introdution


1. CHASECUT

CHASECUT Dn  

Dn:  Synchronous zone flag (fixed point: 0 non-synchronous zone, 1 synchronous zone)

Dn+2:  Alarm flag (fixed point: 0 no alarm, 1 alarm)

Dn+4:  Trimming completion flag (fixed point: 1 Trimming completed, automatically cleared at start-up)

 

//The following data are floating point

Dn+10:  Theoretical speed from axis (floating point: mm/s)

Dn+12:  Theoretical position from axis (floating point: mm)

Dn+14:  Movement of the spindle at the moment of reaching the synchronisation point (floating point: mm)

 

Dn+20:  Spindle speed (floating point: mm/s)

Dn+22:  Spindle position (floating point: mm)

 

Dn+24:  Slave axis acceleration distance (floating point: mm): at this point the spindle travels 1.875 times the distance of the slave axis

Dn+26:  Slave axis synchronisation distance (floating point: mm)

Dn+28 Slave axis deceleration distance (floating point: mm): at this point the spindle travels 1.875 times the distance of the slave axis

Dn+30:  Cam start offset spindle distance (mm)

 

Dn+40:  Closed loop, from axis number (fixed point: 0 to 10, to be set when adding displacement) (double word)

Dn+42:  Closed loop, mode (fixed point: 0 no closed loop; 1 self-closed loop; 2 externally closed loop) (double word)

Dn+44:  Closed loop, adjustment percentage (fixed point: 1 to 100%, other values default to 100%) (spindle speed not available at 100%) (double word)

Dn+46:  Closed loop, from axis position value (floating point) (mm) 

*The slave position should be provided before the condition is switched on

 

2. Frequency-convertible pulses

PLSV  Pulse frequency    Parameter address  Yn

 

3. Frequency measurement

SPD   Number of operations1  Number of operations2  Number of operations3  Number of operations4

 

Number of operations1:Input terminal Xn

Number of operations2: time ms(double word)

Number of operations3:Precision,Constants K1; K10;  K100;  K1000(double words)

Number of operations4:Measured values(double words)

Only the pulses entered for operand 1 are counted within operand 2 x 1 ms time.

The measured value is saved to operand 4;

The current value is saved to operand 4+2;

Remaining time is saved to operand 4+4 (ms);

Repeat this operation to obtain the pulse density (i.e. the value proportional to the speed) in the measured value operand 3.


Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --
Introduce Mochuan MV series plc chasecut instruction

Send your inquiry

Send your inquiry
Choose a different language
English
ภาษาไทย
Deutsch
Español
français
italiano
Português
русский
Current language:English