MOCHUAN MV series PLC Chasecut Instruction introdution
1. CHASECUT
CHASECUT Dn
Dn: Synchronous zone flag (fixed point: 0 non-synchronous zone, 1 synchronous zone)
Dn+2: Alarm flag (fixed point: 0 no alarm, 1 alarm)
Dn+4: Trimming completion flag (fixed point: 1 Trimming completed, automatically cleared at start-up)
//The following data are floating point
Dn+10: Theoretical speed from axis (floating point: mm/s)
Dn+12: Theoretical position from axis (floating point: mm)
Dn+14: Movement of the spindle at the moment of reaching the synchronisation point (floating point: mm)
Dn+20: Spindle speed (floating point: mm/s)
Dn+22: Spindle position (floating point: mm)
Dn+24: Slave axis acceleration distance (floating point: mm): at this point the spindle travels 1.875 times the distance of the slave axis
Dn+26: Slave axis synchronisation distance (floating point: mm)
Dn+28 Slave axis deceleration distance (floating point: mm): at this point the spindle travels 1.875 times the distance of the slave axis
Dn+30: Cam start offset spindle distance (mm)
Dn+40: Closed loop, from axis number (fixed point: 0 to 10, to be set when adding displacement) (double word)
Dn+42: Closed loop, mode (fixed point: 0 no closed loop; 1 self-closed loop; 2 externally closed loop) (double word)
Dn+44: Closed loop, adjustment percentage (fixed point: 1 to 100%, other values default to 100%) (spindle speed not available at 100%) (double word)
Dn+46: Closed loop, from axis position value (floating point) (mm)
*The slave position should be provided before the condition is switched on
2. Frequency-convertible pulses
PLSV Pulse frequency Parameter address Yn
3. Frequency measurement
SPD Number of operations1 Number of operations2 Number of operations3 Number of operations4
Number of operations1:Input terminal Xn
Number of operations2: time ms(double word)
Number of operations3:Precision,Constants K1; K10; K100; K1000(double words)
Number of operations4:Measured values(double words)
Only the pulses entered for operand 1 are counted within operand 2 x 1 ms time.
The measured value is saved to operand 4;
The current value is saved to operand 4+2;
Remaining time is saved to operand 4+4 (ms);
Repeat this operation to obtain the pulse density (i.e. the value proportional to the speed) in the measured value operand 3.
Copyright © 2024 Wuxi Mochuan Drives Technology Co.,Ltd 无锡默川传动技术有限公司- www.mochuan-drives.com All Rights Reserved.